Diagnostic Method
Judge as NG when the following conditions are established.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
|
More than 0.02 V Less than 4.98 V Less than 1.1 V Or, More than 1.4 V Less than 1.819 V Or, More than 3 V |
Time needed for diagnosis:
- 200 ms
- 200 ms
- 200 ms
- 200 ms
Malfunction indicator light illumination: Illuminates as soon as a malfunction occurs.