Installation [06/2015 - ]: Procedure
- INSTALL VACUUM SENSOR (MANIFOLD ABSOLUTE PRESSURE SENSOR)
- Align the protrusion of the vacuum sensor bracket with the hole of vacuum sensor (manifold absolute pressure sensor).
*a Protrusion *b Hole - Install the vacuum sensor (manifold absolute pressure sensor) with the bolt.
Torque: 10 N*m (102 kgf*cm, 7 ft.*lbf)
- Connect the vacuum hose and vacuum sensor (manifold absolute pressure sensor) connector to the vacuum sensor (manifold absolute pressure sensor).
- Align the protrusion of the vacuum sensor bracket with the hole of vacuum sensor (manifold absolute pressure sensor).
- INSTALL NO. 2 CYLINDER HEAD COVER
Refer to PROCEDURE - Step 82