LEMON Manuals: Even more car manuals for everyone

DTC P0500: Vehicle Speed Sensor "A": Procedure

  1. CHECK OPERATION OF SPEEDOMETER 
    1. Drive the vehicle and check whether the operation of the speedometer in the combination meter is normal.

      HINT: 

      • The vehicle speed sensor is operating normally if the speedometer reading is normal.
      • If the speedometer does not operate, check it by following the procedure described in Speedometer Malfunction.

    NG → See step   12 

    OK: Go to next step 

  2. READ VALUE USING TECHSTREAM (VEHICLE SPEED) 
    1. Connect the Techstream to the DLC3.
    2. Turn the ignition switch to ON.
    3. Turn the Techstream on.
    4. Enter the following menus: Powertrain / Engine and ECT / Data List / Vehicle Speed.
    5. Drive the vehicle.
    6. Read the value displayed on the Techstream.

      OK

      Vehicle speeds displayed on the Techstream and speedometer display are equal.

    NG → See step   3 

    OK → See step   8 

  3. CHECK HARNESS AND CONNECTOR (COMBINATION METER - ECM) 
    1. Disconnect the combination meter connector.
    2. Disconnect the ECM connector.
    3. Measure the resistance according the value(s) in the table below.

      Standard Resistance (Check for Open)

      Tester Connection Condition Specified Condition
      C37-20 (+S) - A36-8 (SPD) Always Below 1 Ω

      Standard Resistance (Check for Short)

      Tester Connection Condition Specified Condition
      C37-20 (+S) or A36-8 (SPD) - Body ground Always 10 kΩ or higher

      HINT: 

      If the wire has a short, check the speed signal circuit in other systems related to the vehicle speed signal (e.g. tire pressure warning system, audio system, etc.).

    4. Reconnect the combination meter connector.
    5. Reconnect the ECM connector.

    NG → REPAIR OR REPLACE HARNESS OR CONNECTOR (OTHER SYSTEMS RELATED TO SPEED SIGNAL) 

    OK: Go to next step 

  4. CHECK COMBINATION METER (+S VOLTAGE) 
    Fig 1: Checking Combination Meter (+S Voltage)
    GTY313219Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    1. Disconnect the combination meter connector.

      HINT: 

      Disconnect the ECU connectors on the other systems related to the speed signal (but the ECM connectors must be connected).

    2. Turn the ignition switch to ON.
    3. Measure the voltage according to the value(s) in the table below.

      Standard Voltage

      Tester Connection Switch Condition Specified Condition
      C37-20 (+S) - Body ground Ignition switch ON 4.5 to 5.5 V
      TEXT IN ILLUSTRATION

      *a Front view of wire harness connector
      (to Combination Meter)
    4. Reconnect the combination meter connector.

    NG → See step   10 

    OK: Go to next step 

  5. CHECK COMBINATION METER (SPD SIGNAL OUTPUT WAVEFORM) 
    Fig 2: Checking Combination Meter (SPD Signal Output Waveform)
    GTY310182Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    1. Remove the combination meter.
    2. Connect the combination meter connector.
    3. Move the shift lever to the neutral position.
    4. Jack up the vehicle.
    5. Turn the ignition switch to ON.
    6. Check the voltage between the terminal of the combination meter and the body ground while the wheel is turned slowly.

      Standard Voltage

      Tester Connection Switch Condition Specified Condition
      C37-20 (+S) - Body ground Ignition switch ON
      (Turn wheel slowly)
      Voltage generated intermittently
      TEXT IN ILLUSTRATION

      *a Component with wire harness connected
      (Combination Meter)

      HINT: 

      The output voltage should fluctuate up and down, similarly to the diagram, when the wheel is turned slowly.

    7. Reinstall the combination meter.

    NG → See step   6 

    OK → See step   10 

  6. CHECK COMBINATION METER (SPD SIGNAL INPUT WAVEFORM) 
    Fig 3: Checking Combination Meter (SPD Signal Input Waveform)
    GTY310181Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    1. Remove the combination meter.
    2. Connect the combination meter connector.
    3. Move the shift lever to the neutral position.
    4. Jack up the vehicle.
    5. Turn the ignition switch to ON.
    6. Check the voltage between the terminal of the combination meter and the body ground while the wheel is turned slowly.

      Standard Voltage

      Tester Connection Switch Condition Specified Condition
      C37-19 (SI) - Body ground Ignition switch ON
      (Turn wheel slowly)
      Voltage generated intermittently
      TEXT IN ILLUSTRATION

      *a Component with wire harness connected
      (Combination Meter)

      HINT: 

      The output voltage should fluctuate up and down, similarly to the diagram, when the wheel is turned slowly.

    7. Reinstall the combination meter.

    NG → See step   7 

    OK → See step   9 

  7. CHECK HARNESS AND CONNECTOR (COMBINATION METER - BRAKE ACTUATOR) 
    1. Disconnect the combination meter connector.
    2. Disconnect the brake actuator connector.
    3. Measure the resistance according the value(s) in the table below.

      Standard Resistance (Check for Open)

      Tester Connection Condition Specified Condition
      C37-19 (SI) - A37-11 (SP1) Always Below 1 Ω

      Standard Resistance (Check for Short)

      Tester Connection Condition Specified Condition
      C37-19 (SI) or A37-11 (SP1) - Body ground Always 10 kΩ or higher
    4. Reconnect the combination meter connector.
    5. Reconnect the brake actuator connector.

    NG → REPAIR OR REPLACE HARNESS OR CONNECTOR 

    OK → See step   11 

  8. CHECK FOR INTERMITTENT PROBLEMS. Refer to  CHECK FOR INTERMITTENT PROBLEMS 
  9. REPLACE COMBINATION METER. Refer to  REMOVAL 
  10. REPLACE ECM. Refer to  REMOVAL 
  11. REPLACE BRAKE ACTUATOR ASSEMBLY. Refer to  REMOVAL 
  12. GO TO MALFUNCTION IN SPEEDOMETER. Refer to  Speedometer Malfunction