Inspection Procedure
- CHECK STOP LAMP SWITCH OPERATION (STOP LAMP SWITCH CIRCUIT)
- Check that the stop light comes on when the brake pedal is depressed and goes off when the brake pedal is released.
Standard: Stop lamp switch function is normal.
- NG : Go to step 3
- OK : GO TO NEXT STEP
- Check that the stop light comes on when the brake pedal is depressed and goes off when the brake pedal is released.
- INSPECT SKID CONTROL ECU CONNECTOR (STP1 TERMINAL VOLTAGE)
- Disconnect the skid control ECU connector.
- Measure the voltage according to the value(s) in the table below.
Standard:
SKID CONTROL ECU CONNECTOR VOLTAGE SPECIFICATIONTester Connection Condition Specified Condition STP (S1-10) - GND1 (S1-2) Brake pedal is depressed 11 to 14 V STP (S1-10) - GND2 (S1 -24) Brake pedal is depressed
- NG : Go to step 4
- OK : REPLACE BRAKE ACTUATOR ASSY (See REPLACEMENT )
- INSPECT STOP LAMP SWITCH ASSY
- Disconnect the stop lamp switch connector.
- Measure the resistance according to the value(s) in the table below.
Standard:
STOP LAMP SWITCH CONNECTOR RESISTANCE SPECIFICATIONSwitch Condition Tester Connection Specified Condition Switch pin free 1 - 2 1 Ω or less Switch pin pushed in 1 - 2 10 kΩ or higher (No continuity)
- NG : REPLACE STOP LAMP SWITCH ASSY
- OK : GO TO NEXT STEP
- CHECK HARNESS AND CONNECTOR (STOP LIGHT SWITCH - SKID CONTROL ECU)
- Disconnect the stop lamp switch connector and skid control ECU connector.
- Measure the resistance according to the value(s) in the table below.
Standard:
STOP LAMP SWITCH AND SKID CONTROL ECU CONNECTOR RESISTANCE SPECIFICATIONTester Connection Specified Condition STP (S1-10) - STP (S4-1) 1 Ω or less
- NG : REPAIR OR REPLACE HARNESS OR CONNECTOR
- OK : REPLACE BRAKE ACTUATOR ASSY (See REPLACEMENT )