LEMON Manuals: Even more car manuals for everyone

Circuit/System Testing

WARNING: This page is about a different variant/trim than selected.
  1. Disconnect harness connector X2 from the SGCM. Refer to Generator Control Module Replacement .
  2. Test for 5-100 ohms between terminals 9 and 12.
    • If within the specified range, replace the SGCM.
  3. Disconnect the X1 connector at the MGU. Refer to Generator with Starter Replacement 
  4. Test for less than 1 ohm between SGCM connector harness terminal 12 and the MGU connector harness terminal A.
    • If greater than the specified range, test the circuit for open/high resistance.
  5. Test for less than 1 ohm between SGCM connector harness terminal 9 and the MGU X1 connector harness terminal C.
    • If greater than the specified range, test the circuit for open/high resistance.
  6. If both circuits test normal, replace the MGU.