Automatic Climate Control System Overcompensation And Excessive Electric Parasitic Draw (02-T-03)
Publication date: 2003-05-05Reference number: 02-T-03
AUTOMATIC CLIMATE CONTROL SYSTEM OVERCOMPENSATION AND EXCESSIVE ELECTRIC PARASITIC DRAW
TECHNICAL SERVICE BULLETIN
| SATURN: | 2002 L-Series with automatic climate control (RPO C68) built between and including VINs 2Y500000 and 2Y510600 |
| SECTION: | 01 - HVAC |
CONDITION
Some customers may comment about one or more of the following conditions:
- Overcompensation of HVAC temperature when raising the temperature from cool to warm.
- Overcompensation of HVAC temperature when lowering the temperature from warm to cool.
- Battery has a low voltage charge after extended periods of not being driven.
CAUSE
Install new automatic climate control module calibration P/N 22694049. Refer to "Service Programming System (SPS)" in the Saturn Service Stall System (SSS) User Guide for reprogramming procedures. If calibration P/N 22694049 is already installed, refer to "Automatic Climate Control Diagnostics" in the 2002 L-Series HVAC Service Manual for additional diagnostic information.
WARRANTY INFORMATION
To receive credit for this repair during the warranty coverage period, submit a claim through the Saturn Dealer System for D4707 (Module or Assembly, HVAC Control Head-Reprogram), or if another procedure is performed, refer to the appropriate Electronic Labor Time Guide for the correct Labor Operation Code and Time.