LEMON Manuals: Even more car manuals for everyone

Charge Air Bypass Valve: 4-Cyl

  1. Disconnect the vacuum hose from the bypass valve. See Fig 1.
  2. Connect Pressure/Vacuum Pump (30 14 883) and create a negative pressure in the valve.
  3. Make sure the diaphragm is undamaged. If it is, it will not hold the vacuum.
  4. Repeat steps  2 and  3 , this time creating positive pressure. See Fig 2.
  5. Disconnect the pump.
  6. Connect the vacuum hose.
Fig 1: Depressurizing Charge Air Bypass Valve (4-Cyl)
G00184261Courtesy of SAAB-SCANIA OF AMERICA, INC.
Fig 2: Pressurizing Charge Air Bypass Valve (4-Cyl)