Solenoid valve SL, for Lock-up: Notes

Solenoid valve SL is located in the valve housing which is mounted on the gear case. This solenoid controls the torque converter's Lock-up clutch. When it is activated, power is transmitted mechanically through the torque converter.

The solenoid is grounded via its casing directly to the gear case and is connected to control module pin 2, which activates it by supplying it with B+. A valve not supplied with current is open.

Whether the control module activates the Lock-Up function on 2nd, 3rd or 4th gear depends on the throttle position and the vehicle speed. 2nd gear is special in so much as lock-up is activated for fluid temperatures in excess of 150°C.

The Lock-up function is disengaged if: 

Fig 1: Identifying Solenoid Lock-Up Communication Flow
G03516385Courtesy of SAAB-SCANIA OF AMERICA, INC.
Fig 2: Solenoid Lock-Up Communication Flow Connection Diagram
G03516386Courtesy of SAAB-SCANIA OF AMERICA, INC.

The resistance of the winding in the solenoid is nominally 13 ohms.