Primary Resistance
- Remove connectors from coil primary terminals. Turn ignition "OFF". Set ohmmeter to x1 scale. Attach ohmmeter leads to coil primary terminals.
- Reading should be .4-.8 ohm. If so, but there is no high voltage, replace computer. If resistance is not to specification, replace ignition coil.