Oxygen Sensor
- Connect an exhaust gas analyzer to test point. Warm engine to operating temperature. Disconnect oxygen sensor wire. Note CO% level.
- Disconnect and plug vacuum hose from fuel pressure regulator. The CO% level should increase. Reconnect oxygen sensor wire. The CO level should decrease to 0.6-1.0%. If not, disconnect oxygen sensor. Connect oxygen sensor harness connector terminal to ground.
- Check if the CO% level increases. If not, check wire from CU connector terminal No. 24 to oxygen sensor plug. If no problem is found, replace oxygen sensor.