LEMON Manuals: Even more car manuals for everyone

Circuit/System Verification

    IMPORTANT: All CMP actuator system DTCs must be cleared before the CMP actuator solenoid scan tool output control is enabled.
  1. Engine running at normal operating temperature, command the CMP actuator solenoid ON with the scan tool. The engine should run rough or stall.
  2. Operate the vehicle within the Conditions for Running the DTC to verify the DTC does not reset. You may also operate the vehicle within the conditions that you observed from the Freeze Frame/Failure Records data.