LEMON Manuals: Even more car manuals for everyone

Installation Procedure

    Fig 1: Fitting Motor/Module Assembly Rotor Isolator Over Steering Column Assist Mechanism Input Shaft
    GM1362061Courtesy of GENERAL MOTORS CORP.
    CAUTION: Do NOT allow the wiring harness to be pinched between the motor/module assembly and the steering column during installation. A pinched harness will cause diagnostic trouble codes to be set and may require replacement of the steering column.
    NOTE: Before installing the power steering assist motor (2), verify the rotor isolator bumper (1) is installed into the rotor isolator (3) in the power steering assist motor (2).
  1. Fit the power steering assist motor rotor isolator over the steering column assist mechanism input shaft.
  2. Fig 2: Attaching Motor/Module Assembly To Steering Column
    GM1362063Courtesy of GENERAL MOTORS CORP.
    CAUTION: Refer to Fastener Caution .
  3. Use a M6x1 TORX® head bit to attach the new power steering assist motor bolts (1) and tighten to 9 N.m (80 lb in).
  4. Connect the power steering assist motor sensor wire harness (3) to the power steering assist motor (2).
  5. Install the power steering assist motor sensor wire harness strap clip (4) into the power steering assist motor (2).
  6. Perform the control module setup. Refer to Control Module References .