Circuit Breaker Test
- Circuit breaker is located in micro relay bank, behind center console. Pull outward slightly, ensuring circuit breaker terminals still contact terminals in fuse block.
- Using a voltmeter, connect negative voltmeter lead to good chassis ground. With voltmeter positive lead, check both terminals of circuit breaker for battery voltage.
- If only one terminal has battery voltage, check for a short to ground between circuit beaker and switch. If no short is found, circuit breaker is defective and must be replaced.
- If neither terminal shows battery voltage, check for an open or shorted circuit to circuit breaker.