System Operational Test

  1. Unload vehicle. With ignition off, check riding height. Turn ignition on. Add 300-350 lbs. (136-159 kg) load to trunk. Compressor should start operating after a time delay of approximately 7-15 seconds on "A", "B" and "D" bodies, 7-10 seconds on "C" and "H" bodies or 13-27 seconds on "E" and "K" bodies. Vehicle should rise to 1" (25.4 mm) of curb height on "A", "D", "E" and "K" bodies or 3/4" (19.1) on "B", "C" and "H" bodies.
  2. Remove load from trunk. Exhaust should start within approximately 7-15 seconds on "A", "B" and "D" bodies, 7-10 seconds on "C" and "H" bodies or 13-27 seconds on "E" and "K" bodies. Within 2 minutes, exhaust should stop and vehicle should be within 1" (25.4 mm) of curb height on "A", "D", "E" and "K" bodies or 3/4" (19.1) on "B", "C" and "H" bodies.