All Other Models
- Disconnect pressure line from drier and attach Air Pressure Gauge (J-22124-A ) to drier fitting. Disconnect wiring from compressor motor and exhaust solenoid terminals. See Fig 1 .
- Connect 12-volt power supply to compressor through ammeter. Current draw must not exceed 14 amps. Allow pressure to reach 100 psi (7.03 kg/cm2
) minimum and shut off compressor. Allow pressure to stabilize. Check for pressure leaks.NOTE: If compressor is allowed to run to maximum output pressure of 170 psi (12.3 kg/cm2 ) on Brougham or 180 psi (12.7 kg/cm2 ) on all other models, the solenoid exhaust valve will act as a relief valve. This gives a false indication of system leakage.
- On all models, if compressor operates correctly, reconnect wiring and air lines. If compressor does not operate correctly, refer to TROUBLE SHOOTING in this article.