LEMON Manuals: Even more car manuals for everyone

All Other Models

  1. Disconnect pressure line from drier and attach Air Pressure Gauge (J-22124-A ) to drier fitting. Disconnect wiring from compressor motor and exhaust solenoid terminals. See Fig 1 .
  2. Connect 12-volt power supply to compressor through ammeter. Current draw must not exceed 14 amps. Allow pressure to reach 100 psi (7.03 kg/cm2 ) minimum and shut off compressor. Allow pressure to stabilize. Check for pressure leaks.
    NOTE: If compressor is allowed to run to maximum output pressure of 170 psi (12.3 kg/cm2 ) on Brougham or 180 psi (12.7 kg/cm2 ) on all other models, the solenoid exhaust valve will act as a relief valve. This gives a false indication of system leakage.
  3. On all models, if compressor operates correctly, reconnect wiring and air lines. If compressor does not operate correctly, refer to TROUBLE SHOOTING  in this article.
Fig 1: Testing Electronic Level Control (ELC) Compressor
G90B04758Courtesy of GENERAL MOTORS CORP.