With Consult-III
- Start engine.
- Read "VHCL SPEED SE" in "DATA MONITOR" mode with CONSULT-III. The vehicle speed on CONSULT- III should exceed 10 km/h (6 MPH) when rotating wheels with suitable gear position.
If NG, go to "DIAGNOSIS PROCEDURE ".
If OK, go to following step.
- Select "DATA MONITOR" mode with CONSULT-III.
- Warm engine up to normal operating temperature.
- Maintain the following conditions for at least 60 consecutive seconds.ENG SPEED CONDITION REFERENCE CHART