Diagnosis Procedure
- CHECK CHARGE WARNING LAMP CIRCUIT CONNECTION
Check to see if generator connector F7 terminal 2 is clean and tight.
Is the connection secure?
YES: GO TO 2.
NO: Repair the connection. Confirm repair by performing complete Starting/Charging system test. Refer to Technical Service Bulletin.
- CHECK CHARGE WARNING LAMP CIRCUIT
- Disconnect generator connector F7.
- Apply ground to generator harness connector F7 terminal 2 with the ignition switch in the ON position.
Charge lamp should illuminate
Does it illuminate?
YES: Check generator function. Refer to "WORK FLOW ".
NO: GO TO 3.
- CHECK HARNESS CONTINUITY (OPEN CIRCUIT)
- Turn ignition switch OFF.
- Disconnect the generator connector F7.
- Disconnect the combination meter connector M24.
- Check continuity between generator harness connector F7 terminal 2 and combination meter harness connector M24 terminal 25.
2-25 Continuity should exist
Is there proper continuity?
YES: Replace the combination meter. Refer to "REMOVAL AND INSTALLATION ".
NO: Repair the harness or connector.