LEMON Manuals: Even more car manuals for everyone

Diagnosis Procedure

  1. CHECK TERMINAL "1" CONNECTION
    1. Turn ignition switch OFF.
    2. Check if terminal "1" is clean and tight.

    Is the inspection result normal? 

    YES: GO TO 2.

    NO: Repair terminal "1" connection. Confirm repair by performing complete Starting/Charging system test. Refer to Technical Service Bulletin.

  2. CHECK TERMINAL "1" CIRCUIT

    Check voltage between generator connector F6 terminal 1 and ground.

    1-ground Battery voltage 

    Is the inspection result normal? 

    YES: GO TO 3.

    NO: Check harness for open between generator and fusible link.

    Fig 1: Checking Voltage Between Generator Connector F6 Terminal 1 And Ground
    G04903575
  3. CHECK TERMINAL "1" CONNECTION (VOLTAGE DROP TEST)
    1. Start engine, then engine running at idle and warm.
    2. Check voltage between battery positive terminal and generator connector F6 terminal 1.

    1-B+ Less than 0.2V 

    Is the inspection result normal? 

    YES: Terminal "1" circuit is normal. Refer to "WORK FLOW ".

    NO: Check harness between battery and generator for high resistance.

    Fig 2: Checking Voltage Between Battery Positive Terminal And Generator Connector F6 Terminal 1
    G04903576