DTC P1165 - Swirl Control Valve Control Vacuum Check Switch
- Check Swirl Control Vacuum Hoses
Turn ignition switch to OFF position. Check hoses between swirl control valve solenoid valve, swirl control valve control vacuum check switch and swirl control valve actuator for clogging, cracks or improper connection. See Figure. Repair or reconnect hoses as required. If hoses are okay go to next step.
- Check Ground Circuit
Turn ignition switch to OFF position. Disconnect swirl control valve control vacuum check switch harness connector. Using an ohmmeter, check continuity between switch harness connector terminal No. 1 (Black wire) and ground. If no continuity exists, repair open in Black wire. If continuity exists, go to next step.
- Check Input Signal Circuit
Turn ignition switch to ON position. Using a voltmeter, measure voltage between switch harness connector terminal No. 2 (Red/Yellow wire) and ground. If voltage is not approximately 5 volts, repair fault in Red/Yellow wire. If voltage is approximately 5 volts, go to next step.
- Checking Component
Inspect swirl control components. See procedures in the SYSTEM/COMPONENT TESTS