LEMON Manuals: Even more car manuals for everyone

Work Procedure

WARNING: This page is about a different car, the 2024 Mitsubishi Outlander. However, it is still accessible from the selected car via links, so may be relevant.
  1. TCU REPLACEMENT 

    Replace TCU. Refer to REMOVAL & INSTALLATION .

    >>

    GO TO  2.

  2. PERFORM TCU CONFIGURATION 

    WITH M.U.T.-III SE

    Perform configuration (TCU). Refer to DESCRIPTION .

    GO TO  3.

  3. MANUAL WRITING OF VIN DATA TO TCU 

    WITH M.U.T.-III SE

    1. Turn ignition switch ON and wait at least 5 seconds.
    2. Select "Chassis No./VIN Registration" of "Special Function" item using M.U.T.-III SE.
    3. Touch "OK" at "Chassis No./VIN Registration" screen to write the VIN data into new TCU.

      >>

      GO TO  4.

  4. TCU ACTIVATION 

    Perform TCU activation. Refer to WORK PROCEDURE .

    >>

    GO TO  5.

  5. CHECK NETWORK INITIAL SETTINGS 

    M.U.T.-III SE Special Function

    With MITSUBISHI CONNECT

    1. Confirm 90 or more seconds passed after turning ignition switch ON, then select "Network initial settings" of "IVC".
    2. Check the "Radio wave condition". If it is normal, go to the next step. If the condition is abnormal or cannot be detected, move the vehicle to a place where the radio wave environment is good. Then start from Step  1 again.
    3. Select "Network initial settings" of "MULTI AV".
    4. Check the value of "Network initial setting state". If "Completed" is displayed, the setting is completed. If the value doesn't become "Completed" in 15 minutes, error may occur in the network setting.

      Without MITSUBISHI CONNECT

    5. Confirm 90 or more seconds passed after turning ignition switch ON, then select "Network initial settings" of "IVC".
    6. Check the "Radio wave condition". If it is normal, go to the next step. If the condition is abnormal or cannot be detected, move the vehicle to a place where the radio wave environment is good. Then start from Step  1 again.
    7. Check the value of "Network initial setting state". If "Completed" is displayed, the setting is completed. If the value doesn't become "Completed" in 15 minutes, error may occur in the network setting.

      >>

      INSPECTION END