Seatback Heater Check

Measure the resistance between terminals.

Standard value: At room temperature 20 °C (68 °F) 

Approximately 4.6 ohm +/- 10% 

Fig 1: Measuring Resistance Between Terminals 1 And 3
G02496386Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.