LEMON Manuals: Even more car manuals for everyone

Ignition Failure Sensor: Testing and Inspection




IGNITION FAILURE SENSOR CHECK

NOTE: An analog-type ohmmeter should be used. Check that the resistance between terminals 3 and 4 is at the standard value.

Standard value: 0.1 Ohms or less