Service Campaign 2020080013 Clean SRS Control Unit Contacts (P-SC-2020080013)
Reference number: P-SC-2020080013
Supersedes refnos: 2020080013
SERVICE CAMPAIGN 2020080013 CLEAN SRS CONTROL UNIT CONTACTS
SERVICE CAMPAIGN BULLETIN
| MERCEDES-BENZ: | MY19-21 118, 177, 247 (CLA-Class, A-Class, GLA-Class GLB-Class) |
SERVICE INFORMATION
IMPORTANT NEW SERVICE CAMPAIGN LAUNCH INFORMATION
IN-VEHICLE NOTIFICATION
To enhance the Mercedes-Benz customer experience, an in-vehicle notification will be sent to the affected vehicles for this service campaign. The notification will be sent to approximately 6,000 VINs per week. An example of the message that will appear in a flagged vehicle is shown below.
This message will appear at engine start beginning September 7, 2020 and will continue every 30 days until the service campaign has been completed. Dealers are reminded to submit warranty claims in a timely manner to reduce the possibility of redundant messages.
Please note that all customer inquiries should be directed to the Customer Assistance Center at 1-800-FOR-MERCEDES.
Sincerely,
Gregory Gunther
Department Manager, Vehicle Compliance & Analysis
Campaign No. 2020080013, September 2020
TO: ALL MERCEDES-BENZ CENTERS
SUBJECT
Model CLA-Class, A-Class, GLA-Class and GLB-Class (118, 177, and 247 platform) Model Year 2019-2021
Clean SRS Control Unit Contacts
Mercedes-Benz AG ("MBAG"), the manufacturer of Mercedes-Benz, has determined that on certain MY19-21 CLA-Class, A-Class, GLA-Class and GLB-Class (118, 177, and 247 platform) vehicles, an increased electrical resistance may occur between the connector block of the electronic control unit and the connector pins for the Supplemental Restraint System (SRS) wiring harness. The SRS control unit might detect the increased resistance in various SRS circuits (e.g. driver/front passenger airbag, seat belt tensioner) which could lead to illumination of a warning message (yellow) and a warning lamp (red) in the instrument cluster. The functionalities of the SRS system are not impaired. MBUSA will conduct a Service Campaign. An authorized Mercedes-Benz dealer will inspect and clean the SRS control unit connector contacts. Customers included in this Service Campaign will be notified through in-vehicle notification in waves of approx. 6000 per week with subsequent notices sent every 30 days.
Prior to performing this Campaign:
- VMI must always be checked before performing campaigns to verify that the campaign is required on a specific vehicle. Always check for any other open campaigns, and perform accordingly.
- Please review the entire Campaign bulletin and follow the repair procedure exactly as described.
Approximately 38,627 vehicle is affected.
Order No. P-SC-2020080013
This bulletin has been created and maintained in accordance with MBUSA-SLP S423QH001, Document and Data Control, and MBUSA-SLP S424HH001, Control of Quality Records.
Test tool must be prepared before the work procedure.
See description "Preparation of test tool" on page 9 and 10.
Before beginning work, no SRS fault message may be present in the instrument cluster!
If a SRS fault message is present before the start of work, it must be rectified.
The fault rectification may not be invoiced together with the campaign.
WORK PROCEDURE
- Disconnect ground line of on-board electrical system battery.
For basic data, see AR54.10-P-0003MFA .
- Fold away left and right floor covering in area of center console and place powertrain control unit (A, figure 1)
with connected lines to one side.
For basic data on control unit removal, see AR91.60-P-0615MFA .
Contrary to the work instructions in WIS, the center console does not have to be disassembled.
- Disconnect the contacts of both electrical connectors (20 - and 104-pin)
of the Supplemental Restraint System control unit (SRS) (figures 2 - 4)
.
To release the 20-pin plug, push the red locking clip (B, figure 2) in the direction of the arrow.
To disconnect the 20-pin plug (C, figure 3), press the lock downwards (in direction of the arrow) by using an allen wrench.
- Release three nuts (D, figure 4)
for the Supplemental Restraint System control unit (SRS)
and remove this.
- Place Supplemental Restraint System control unit (SRS)
on the ESD
mat for processing at the workplace.
The contacts of the Supplemental Restraint System control unit (SRS) may not be touched.
- Clean all electrical connection pins in the control unit with extreme caution
by means of cleaning brushes (C, figures 5 and 6)
.
6 cleaning brushes (figures 7) . For the complete cleaning procedure a total of six cleaning brushes must be used.
Observe the information on preventing damage to the electronic components due to electrostatic discharge AH54.00-P-0001-01A.
Ensure extreme cleanliness.
Slide cleaning brushes in insertion direction onto the connection pins up to end stop and remove again (figures 5 and 6).
The cleaning brushes must be placed parallel to the lower edge of the control unit (Figures 5, 6 and 8).
An insertion of the cleaning bushes 90° offset to the lower edge of the control unit can result in damage to the connection pins (figures 9 and 10).
All movements at the connectors must be executed in a linear manner in order to not damage (bend) the pins.
Do not twist. A twisting of the cleaning brush can damage or bend the adjacent contacts.
Up to two connection pins can be cleaned simultaneously.
All connection pins must be cleaned. No connection pins may be omitted.
Observe the cleaning sequence in operation step 7.
- Perform cleaning in the following sequence:
The SRS control unit has 4 connection rows (1-4 figure 9).
A total of 6 cleaning brushes are required for the complete cleaning process.
- Connection rows 1 and 2 must be fully cleaned with a cleaning brush. Repeat this process two more times with a new cleaning brush for each time.
- Connection rows 3 and 4 must be fully cleaned with a cleaning brush. Repeat this process two more times with a new cleaning brush for each time.
Each contact is thus cleaned three times.
No cleaning agents or similar may be used with the cleaning brush.
Check for damage after cleaning:
- Slide on
the test coupling (104-pin and 20-pin)
from above onto the cleaned SRS control unit without any force
up to the end stop and remove the test coupling (figure 11 and 12).
The objective is to detect with this empty coupling housing whether the pins are OK and not bent after the cleaning.
If both test couplings can be inserted without any force up to the end stop (see F and G figures 11 and 12), the pins are OK.
In the case of damaged control unit pins, the SRS control unit is unusable and must be replaced (dispose of the control unit properly).
The contact carriers must be fully inserted in the support body of the coupling housing and align with the control unit edge (F, figure 11).
The support body of the 20-pin male test connector must align with the control unit edge (G, figure 12).
The test tools can be reused (see annex "Preparation of test tool" on page 9.
- Visual inspection of the pins in the control unit (figure 13).
No control unit pins may be bent.
In the case of damaged control unit pins, the SRS control unit is unusable and must be replaced.
For basic data, see AR91.60-P-0615MFA.
- Make the used cleaning bushes unusable at the end of the cleaning work (figure 14)
.
Cleaning brushes may not be reused.
- Assemble in reverse order.
First tighten the SRS control unit with the correct torque ( Nm 10) and then connect.
For basic data, see AR91.60-P-0615MFA .
- Switch ignition to position 1 . To do so, press start button once without touching the brake pedal. Check whether airbag indicator lamp (H, figure 15) permanently goes off after a few seconds.
The SRS check is thus completely ensured.
PREPARATION OF TEST TOOL
The test tools (104-pin and 20-pin) must only be produced once per workshop and reused. The test tools must be stored in a clean, dry, and secure location.
A visual inspection must be carried out before every use. As soon as contamination or damage is noticeable, this test tool must be replaced by a new one. Dispose of the old test tool.
- Remove retaining bracket (figure 16)
from coupling housing (A 029 545 90 26)
and dispose of it.
- Insert both contact carriers with low effort
into the coupling housing up to the end stop (figure 17).
Retaining lugs of contact carriers must engage.
- Assemble airbag control unit coupling housing (A 166 545 04 26)
and contact carrier (A 005 545 23 40) (figure 18 and 19).
Insert contact carrier (yellow) of 20-pin plug with low effort in coupling housing (black) up to
- Carefully remove locking clip (red) and engagement lever (black) from the plug housing and subsequently dispose of (figure 20) .
SPECIAL TOOLS
| Qty. | Part Name | Part Number |
|---|---|---|
| 1 | ESD kit | W 000 589 52 98 00 |
PARTS
| Qty. | Part Name | Part Number |
|---|---|---|
| 6 | Cleaning bush | A 000 540 38 04 |
TEST TOOL PARTS INFORMATION
| Qty. | Part Name | Part Number | ||
|---|---|---|---|---|
| 1(1) | Coupling housing | A 029 545 90 26 | ||
| 1(1) | Contact carrier | A 005 545 53 40 | ||
| 1(1) | Contact carrier | A 005 545 54 40 | ||
| 1(1) | Airbag control unit coupling housing | A 166 545 04 26 | ||
| 1(1) | Contact carrier | A 005 545 23 40 | ||
|
||||
WARRANTY INFORMATION
Operation: Clean pins at control unit (SRS)(02-1056)
Includes: Disconnect and reconnect the battery.
| Damage Code | Operation Number | Labor Time (hrs.) |
|---|---|---|
| 91 921 08 7 | 02-1056 | 0.6 |