New Systems Charging Strategy (TT 08/11-E)
Publication date: 2011-08-01Reference number: TT 08/11-E
NEW SYSTEMS CHARGING STRATEGY
DEALER TECH TOPICS; AUGUST 2011
Reference Number(s): TT 08/11, Date of Issue:
August 2011
| MERCEDES-BENZ: | Starting with Model 212 |
| GROUP: | 54.10 - Battery, power supply |
CAUSE / EXPLANATION
New energy management strategy to reduce fuel consumption and emissions. Regenerative charging occurs during braking and the systems battery is utilized more than prior models during acceleration.
CORRECTION
Some customer complaints may arise with this new strategy. On deceleration a driver may feel more engine braking due to a fully loaded alternator. Alternatively, on acceleration with a heavily laden systems battery, consumer shut-off may become active. i.e. the AC blower speed may be momentarily reduced from a high setting. This appears to be most evident on diesel models after start-up due to glow plug activation. i.e. "after glow" during warm-up AND "cylinder warming" during deceleration.
NOTE:
A properly functioning "battery sensor" B95 is critical to the proper function of this new charging strategy. B95 can be tested as outlined in LI54.10-P-051049
. In addition a fixed voltage of U=14.3 V can be selected as a diagnostic tool in the rear SAM.