Continuity Inspection
NOTE:
- The up position switch is built into the selector lever component.
- Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION .)
- Remove the following parts:
- Selector lever knob (See AUTOMATIC TRANSMISSION SHIFT MECHANISM REMOVAL/INSTALLATION .)
- Shift panel component (See SHIFT PANEL REMOVAL/INSTALLATION .)
- Disconnect the selector lever component connector.
- Verify that the continuity between selector lever component terminals C and H.
- If not as verified, replace the selector lever component. (See AUTOMATIC TRANSMISSION SHIFT MECHANISM REMOVAL/INSTALLATION .)
UP SWITCH SPECIFICATIONTest condition Continuity Selector lever is in the M position (+) side position. Continuity Selector lever is not in the M position (+) side position. No continuity