Fuel Pump (Low-pressure Side) Operation Inspection
- Connect the M-MDS to the DLC-2.
- Remove the fuel-filler cap.
- Switch the ignition ON (engine off).
- Turn the fuel pump relay from off to on using the [FUEL_PUMP_REQ] simulation item and inspect if the operation sound of the fuel pump is heard. (See SIMULATION INSPECTION
.)
- If operation sound is heard, fuel pump is normal.
- If no operation sound is heard, proceed to the next step.
- Measure the voltage at the wiring harness side fuel pump unit terminal A with the [FUEL_PUMP_REQ] PID turned on.
- If the voltage is as specified, inspect the following:
- Fuel pump continuity
- Fuel pump ground
- Wiring harness between the fuel pump relay and PCM terminal 2AW
- If not as specified, inspect the following:
- Fuel pump relay (Refer to [RELAY INSPECTION ] in service information.)
- Wiring harness connector (DC-DC converter (i-ELOOP)-Fuel pump relay-Fuel pump unit) (With i-ELOOP)
- Wiring harness connector (Battery-Fuel pump relay-Fuel pump unit) (Without i-ELOOP)
Specification
8.0-11.5 V (Ignition switched ON)
- If the voltage is as specified, inspect the following: