LEMON Manuals: Even more car manuals for everyone

Continuity Inspection

  1. Remove the battery cover. (See BATTERY REMOVAL/INSTALLATION [SKYACTIV-G 2.0] .)
  2. Disconnect the negative battery cable. (See BATTERY REMOVAL/INSTALLATION [SKYACTIV-G 2.0] .)
  3. Remove the neutral switch. (See NEUTRAL SWITCH REMOVAL/INSTALLATION .)
  4. Inspect for continuity between neutral switch terminal A and B.
    Fig 1: Inspecting Neutral Switch
    G08155522
    SPECIFICATION

    Measured condition Continuity
    Rod pushed Continuity detected
    Except above No continuity