LEMON Manuals: Even more car manuals for everyone

Air Gap Inspection

  1. Verify that the CKP sensor is securely installed.
  2. Using a thickness gauge, measure the air gap between the plate projections at the back of crankshaft pulley and the CKP sensor.
    • If not within the specification, inspect the plate projections for cracks or bending.

    Air gap 0.5-1.5 mm {0.02-0.05 in} 

    Fig 1: Identifying Air Gap Between Projection And CKP Sensor
    G06940778Courtesy of MAZDA MOTORS CORP.