No. 3 Will Not Crank
POSSIBLE CAUSE
| 3 | WILL NOT CRANK |
|---|---|
| DESCRIPTION | The starter does not work. |
| POSSIBLE CAUSE |
|
DIAGNOSTIC PROCEDURE
| STEP | INSPECTION | RESULTS | ACTION | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 |
NOTE:
Connect the WDS or equivalent to the DLC-2. Do the following conditions appear?
|
Yes | Both conditions appear: Go to Step 4. |
||||||||||
| No | Either or other condition appears: Go to the next step. |
||||||||||||
| 2 | Turn the ignition switch to the ON position. Is the coil connector securely connected to the coil? | Yes | Go to the next step. | ||||||||||
| No | Connect the coil connector securely. Return to Step 1. |
||||||||||||
| 3 | Does the security light flush? | Yes | Go to the next step. | ||||||||||
| No | Inspect instrument cluster and wiring harness. (See INSTRUMENT CLUSTER INSPECTION ). |
||||||||||||
| 4 | Connect the WDS or equivalent to the DLC-2 and retrieve DTC. DTC B1213, B2139, B2141, B1600, B1601, B1602, B1681, B2103, B2431, U2510 |
Yes | Go to appropriate DTC inspection. (See DTC TABLE ). |
||||||||||
| No | Go to the next step. | ||||||||||||
| 5 | Inspect for the following wiring harnesses and connectors:
Is there any malfunction? |
Yes | Repair or replace suspected wiring harness and connector. | ||||||||||
| No | Go to the next step. | ||||||||||||
| 6 | Inspect for the following wiring harnesses and connectors:
Is there any malfunction? |
Yes | Repair or replace suspected wiring harness and connector. | ||||||||||
| No | Go to the next step. | ||||||||||||
| 7 | Is there continuity between PCM terminal 1B(1), 1AB(2) and starter relay with clutch pedal depressed (MTX with starter interlock system), P or N position (ATX)? | Yes | Go to the next step. | ||||||||||
| No | Repair or replace wiring harness. | ||||||||||||
| 8 | Inspect the following:
Are all items normal? |
Yes | Go to the next step. | ||||||||||
| No | Service if necessary. Repeat Step 8. |
||||||||||||
| 9 | Is clicking sound heard from starter when the ignition switch is turned to START? | Yes | Go to the next step. | ||||||||||
| No | Go to Step 11. | ||||||||||||
| 10 | Inspect the starting system. (See STARTER INSPECTION ). Is starting system normal? |
Yes | Inspect for seized/hydro locked engine, flywheel or drive plate. (See FLYWHEEL INSPECTION ). |
||||||||||
| No | Repair or replace components if required. | ||||||||||||
| 11 | Do any other electrical accessories function? | Yes | Go to the next step. | ||||||||||
| No | Inspect the charging system. (See BATTERY INSPECTION [LF, L3] ). (See GENERATOR INSPECTION [LF, L3] ). |
||||||||||||
| 12 |
NOTE:
Connect the WDS or equivalent to the DLC-2. Access TR PID.Turn the ignition switch to the ON position. Is TR PID indicated P/N when selecting P or N position?
|
Yes | Go to the next step. | ||||||||||
| No | Inspect adjustment of TR switch. If TR switch is adjusted properly, inspect for open circuit between TR switch and PCM terminal 1AH(3), 1U(4), 1S(5) or starter. |
||||||||||||
| 13 | Connect the WDS or equivalent to the DLC-2. Turn the ignition switch to the ON position (Engine off). Retrieve any DTCs. Are there any DTCs displayed? |
Yes | DTC is displayed: Go to appropriate DTC inspection. (See DTC TABLE ). Communication error message is displayed: Inspect for the following:
|
||||||||||
| No | No DTC is displayed: Inspect the following:
|
||||||||||||
| 14 |
|
||||||||||||
|
|||||||||||||