DTC P2402

DETECTION CONDITION AND POSSIBLE CAUSE (DTC P2402 - LF, L3)

DTC P2402 EVAP system leak detection pump motor circuit high
DETECTION CONDITION 
  • The PCM monitors pump load current (EVAP line pressure), while evaporative leak monitor is operating. If the pump load current is higher than specified, the PCM determines EVAP system leak detection pump motor circuit has a malfunction.
  • Diagnostic support note 

  • This is a intermittent monitor (CCM).
  • The MIL illuminates if PCM detects the above malfunction condition in two consecutive drive cycles or in one drive cycle while DTC for the same malfunction has been stored in PCM.
  • PENDING CODE is available if PCM detects the above malfunction condition during first drive cycle.
  • FREEZE FRAME DATA is available.
  • DTC is stored in PCM memory.
POSSIBLE CAUSE 
  • EVAP system leak detection pump malfunction
  • Short to power circuit between the EVAP system leak detection pump terminal D and PCM terminal 1U (1), 1AF (2)
  • PCM malfunction
G04313433Courtesy of MAZDA MOTORS CORP.
(1) LF MTX, L3 and California emission regulation applicable model with LF ATX
(2) Except for California emission regulation applicable model with LF ATX
DIAGNOSTIC PROCEDURE CHART

STEP INSPECTION ACTION
1 VERIFY FREEZE FRAME DATA AND DIAGNOSTIC MONITORING TEST RESULTS HAVE BEEN RECORDED 
  • Have FREEZE FRAME DATA and DIAGNOSTIC MONITORING TEST RESULTS (CCM related) been recorded?
Yes Go to the next step.
No Record FREEZE FRAME DATA and DIAGNOSTIC MONITORING TEST RESULTS on repair order, then go to the next step.
2 VERIFY RELATED REPAIR INFORMATION AVAILABILITY 
  • Check for related Service Bulletins and/or online repair information availability.
  • Is any related repair information available?
Yes Perform repair or diagnostic according to available repair information.
  • If vehicle is not repaired, then go to the next step.
No Go to the next step.
3 INSPECT EVAP SYSTEM LEAK DETECTION PUMP CIRCUIT FOR SHORT TO POWER 
  • Turn the ignition switch to the ON position.
  • Disconnect the EVAP system leak detection pump connector.
  • Measure the voltage between EVAP system leak detection pump terminal D (wiring harness-side) and body ground.
  • Is the voltage B+  ?
Yes Repair or replace the wiring harness, then go to the next step.
No Go to the next step.
4 VERIFY TROUBLESHOOTING OF DTC P2402 COMPLETED 
  • Make sure to reconnect all disconnected connectors.
  • Clear the DTC from the PCM memory using the WDS or equivalent.
  • Perform the evaporative system test using the WDS or equivalent.

    (See EVAP SYSTEM LEAK INSPECTION USING WDS OR EQUIVALENT ).

  • Is the same DTC present?
    NOTE:
    • If evaporative system test function is not available, perform the following procedure:
    • Perform the EVAP System Repair Verification Drive Mode.

      (See OBD-II DRIVE MODE ).

    • Is the PENDING CODE the same as the DTC present?
Yes Replace the PCM, then go to the next step.
No Go to the next step.
5 VERIFY AFTER REPAIR PROCEDURE  Yes Go to the applicable DTC inspection.
(See DTC TABLE ).
No Troubleshooting completed.
(1) LF MTX, L3 and California emission regulation applicable model with LF ATX
(2) Except for California emission regulation applicable model with LF ATX