Temperature Control Switch
- Turn ignition on. Connect voltmeter positive lead to terminal A10 and negative lead to terminal A17 of control unit connector "A". See Figure and Figure .
- With temperature lever on lowest setting, voltage should be zero. As temperature lever is gradually increased toward highest setting, voltage should increase to 5 volts.
- Move positive lead to terminal A4. About 5 volts should be present. If about 5 volts are not present, replace A/C control unit.