Disassembly & Inspection
Remove inner rotor and shaft assembly. Remove outer rotor. Clean all components then reinstall rotors in pump body with chamfered edge of outer rotor at driving end of pump body. Place straightedge across face of pump body and check clearance between straightedge and rotors. Clearance should not exceed 0.0004" (0.1 mm). Check clearance between inner and outer rotors and pump body. Clearance between the inner and outer rotors, measured at the rotor lobes should not exceed 0.010" (0.25 mm). Clearance between outer rotor and pump body should not exceed 0.008" (0.2 mm). If clearance is excessive at any location, pump should be replaced.