On-Demand Self-Test
NOTE:
For further information on ABS diagnostics and testing, see appropriate MODULE COMMUNICATIONS NETWORK article in ACCESSORIES & EQUIPMENT.
NOTE:
On-Demand Self-Test may be used to verify operation of a selected module.
- Connect New Generation Star (NGS) Tester (007-00500) on Data Link Connector (DLC) according to manufacturer's instructions. If necessary, see EQUIPMENT HOOK-UP and DIAGNOSTIC PROCEDURE SEQUENCE in appropriate MODULE COMMUNICATIONS NETWORK article in ACCESSORIES & EQUIPMENT.NOTE: If instructed to perform On-Demand Self-Test from a specified test procedure, ensure ignition switch is in proper position as listed in test procedure.
- Perform DATA LINK DIAGNOSTIC TEST. If tester responds with CKT 914, CKT 915, or CKT 70, ALL ECU'S NO RESP/NOT EQUIP., go to appropriate MODULE COMMUNICATIONS NETWORK article in ACCESSORIES & EQUIPMENT. Test and repair these circuit before proceeding.
- If tester responds with NO RESP/NO EQUIP for ABS control module, go to TEST A . If tester responds with SYSTEM PASSED, retrieve and record continuous Diagnostic Trouble Codes (DTC), erase continuous diagnostic codes and perform self-test for ABS control module.