Inspection [08/2015 - ]: Procedure
- INSPECT ABSORBER CONTROL ACTUATOR
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
FOR LHTester Connection Condition Specified Condition 1 (FAL+) - 2 (FAL-) Always 6.4 to 7.2 Ω 3 (FBL+) - 4 (FBL-) 6.4 to 7.2 Ω TEXT IN ILLUSTRATION*a Component without harness connected
(Absorber Control Actuator LH)If the result is not as specified, replace the absorber control actuator.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
FOR RHTester Connection Condition Specified Condition 1 (FAR+) - 2 (FAR-) Always 6.4 to 7.2 Ω 3 (FBR+) - 4 (FBR-) 6.4 to 7.2 Ω TEXT IN ILLUSTRATION*a Component without harness connected
(Absorber Control Actuator RH)If the result is not as specified, replace the absorber control actuator.
- Measure the resistance according to the value(s) in the table below.