Terminals Of Ecu
- CHECK PARKING ASSIST ECU
- Disconnect the F36 and F37 ECU connectors.
- Measure the voltage and resistance according to the value (s) in the table below.VOLTAGE AND RESISTANCE CHART
Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition F36-6 (+B) - F36-4 (GND1) L - W-B Power source signal Always 11 to 14 V F36-1 (IG) - F36-4 (GND1) G - W-B IG power source signal Engine switch on (IG) 11 to 14 V F36-1 (IG) - F36-4 (GND1) G - W-B IG power source signal Engine switch off Below 1 V F36-14 (ACC) - F36-4 (GND1) GR - W-B ACC power source signal Engine switch on (ACC) 11 to 14 V F36-14 (ACC) - F36-4 (GND1) GR - W-B ACC power source signal Engine switch off Below 1 V F37-22 (BLSW) - F36-4 (GND1) G - W-B Front and side monitor main switch power source signal Engine switch on (IG), front and side monitor main switch on 11 to 14 V F37-22 (BLSW) - F36-4 (GND1) G - W-B Front and side monitor main switch power source signal Engine switch on (IG), front and side monitor main switch off Below 1 V F36-4 (GND1) - Body ground W-B - Body ground ECU ground Always Below 1 Ω - Reconnect the F36 and F37 ECU connectors.
- Measure the voltage according to the value (s) in the table below.VOLTAGE SPECIFICATION
Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition F37-15 (BCV-) - F36-4 (GND1) Shield - W-B Front television camera ground (shielded) Always Below 1 V F37-38 (BGND) - F36-4 (GND1) W - W-B Front television camera ground Always Below 1 V F37-37 (BCV+) - F36-4 (GND1) R - W-B Display signal Wide view front monitor display screen displayed Waveform 1 F37-37 (BCV+) - F36-4 (GND1) R - W-B Display signal Camera lens covered to make image black while wide view front monitor display screen displayed Waveform 2 F37-16 (BCB+) - F36-4 (GND1) B - W-B Front television camera power source signal Wide view front monitor display screen displayed 5.8 to 6.5 V - Using an oscilloscope, check the waveform.
Waveform 1 (Reference)
WAVEFORM REFERENCEItem Content Terminal No. (Symbol) F37-37 (BCV+) - F36-4 (GND1) Tool Setting 0.2 V/DIV., 20 μs/DIV. Condition Wide view front monitor display screen displayed - Using an oscilloscope, check the waveform.
Waveform 2 (Reference)
WAVEFORM REFERENCEItem Content Terminal No. (Symbol) F37-37 (BCV+) - F36-4 (GND1) Tool Setting 0.2 V/DIV., 50 ms/DIV. Condition Camera lens covered to make image black while wide view front monitor display screen displayed
- CHECK DISPLAY AND NAVIGATION MODULE DISPLAY (See TERMINALS OF ECU )