Control Circuit Inspection
- Ignition switch "OFF"
- Refer to "OIL HYDRAULIC MOTOR (ACTUATOR) " and disconnect Oil Hydraulic Motor connector.
- Ignition switch "ON"
- Measure the voltage between Pin No. 1 (+) terminal of Oil Hydraulic Motor harness connector and chassis ground.
Specification: Approx. 10.5V
- Measure the voltage between Pin No. 2 (-) terminal of Oil Hydraulic Motor harness connector and chassis ground.
Specification: Approx. 1.4V
- Ignition switch "OFF"
- Connect Oil Hydraulic Motor connect.
- Set-up the VMI to KDS and run the "Oscilloscope" with KDS (2 Channel):
Channel A (+): Pin No. 1 (+) terminal (Oil Hydraulic Motor connector)
Channel A (-): Ground
Channel B (+): Pin No. 2 (-) terminal (Oil Hydraulic Motor connector)
Channel B (-): Ground.
- Ignition switch "ON"
Specification: Channel A: Approx. 4.8V/Channel B: Approx. 4.8V
- Is the measured value within specification?
YES
- Go to "COMPONENT INSPECTION " procedure.
NO
- Repair open or short in control circuit and then go to "VERIFICATION OF REPAIR " procedure.