Charging System Test Procedure
- Press ENTER to begin charging system test.
- ENTER button is pressed, the tester displays the actual voltage of alternator.
Press ENTER to test the charging system.
- Turn off all electrical load and rev engine for 5 seconds with pressing the accelerator pedal.
- Press ENTER.
- The MICRO 570 analyzer charging system output at idle for comparison to other readings.
- Take a relevant action according to the test results by referring to the CHARGING SYSTEM TEST RESULTS table below after shutting off the engine and disconnect the tester clamps from the battery.CHARGING SYSTEM TEST RESULTS
RESULT ON PRINTER REMEDY Charging system normal/Diode ripple normal Charging system is normal No charging voltage Generator does not supply charging current to battery
=> Check belts, connection between generator and battery
Replace belts or cable or generator as necessaryLow charging voltage Generator does not supply charging current to battery and electrical load to system fully
=> Check belts and generator and replace as necessaryHigh charging voltage The voltage from generator to battery is higher than normal limit during voltage regulating.
=> Check connection and ground and replace regulator as necessary
=> Check electrolyte level in the batteryExcess ripple detected One or more diodes in the generator is not functioning properly
=> Check alternator mounting and belts and replace as necessary