LEMON Manuals
: Even more car manuals for everyone
Home
›
Kia
›
2001
›
Magentis (CANADA) V6-2.5L
›
Repair and Diagnosis
›
Heating and Air Conditioning
›
Ambient Temperature Sensor / Switch HVAC
›
Testing and Inspection
Ambient Temperature Sensor / Switch HVAC: Testing and Inspection
1.
Disconnect battery terminal (-).
2.
Detach the harness of the ambient temperature sensor.
3.
Measure the resistance as shown.
Resistance
20 °C 36.5 ± 2.3 kOhms