LEMON Manuals: Even more car manuals for everyone

Canister Purge Control Valve

  1. Remove canister from vehicle. Apply 7.5 psi air pressure to port marked "VC". Air should not leak from diaphragm. See Fig 1 .
  2. Apply and maintain 15 in. Hg vacuum to port marked "PURGE". Gradually apply vacuum to "VC" port. Purge valve should begin to open when 7.1-8.7 in. Hg vacuum is applied to port "VC". Replace valve if it does not operate as outlined.
Fig 1: Testing Purge Control Valve This does not apply to Impulse.
G37913