Horn Reminder Check
- CHECK HORN
Check if horn sounds with horn switch.
Does horn operate?
- Yes : GO TO 2.
- No : Check horn circuit.
- CHECK HORN REMINDER OPERATION
- Disconnect smart entrance control unit connector.
- Apply ground to smart entrance control unit terminal 19.
Refer to Wiring Diagram - Multi - .
Does horn sound?
- Yes : Replace smart entrance control unit.
- No : Check harness for open or short between smart entrance control unit and horn relay.