Repair Procedures: Inspection
Signal Circuit Inspection
- Check ignition lock switch pull-up voltage
- IG KEY "OFF", ENGINE "OFF".
- Disconnect ignition lock switch connector.
- IG KEY "ON".
- Measure the voltage between signal terminal of ignition lock switch harness connector and chassis ground.
Specification : 11.5V ~ 13.0V
- Check open in ignition lock switch signal circuit
- IG KEY "OFF", ENGINE "OFF".
- Disconnect ignition lock switch connector and ECM connector.
- Check continuity between signal terminal of lock switch signal harness connector and ECM harness connector.
Specification : Continuity (below 1.0 Ω)
Ground Circuit inspection
- IG KEY "OFF", ENGINE "OFF".
- Disconnect ignition lock switch connector.
- Check continuity between lock switch signal connector terminal 1 and chassis ground.
Specification : Continuity (below 1.0 Ω)
Component Inspection
- Remove the ignition lock switch
- Push the ignition lock switch in the direction of the arrow to make sure that continuity between terminals. (refer to the table below)
Standard value :
Full stroke (A): 12.0 ± 0.3 mm (0.4724 ± 0.0118 in.)
ON-OFF point (B): 2.0 mm (0.0787 in.)