LEMON Manuals: Even more car manuals for everyone

Ground Circuit Inspection

  1. IG "OFF" and disconnect OTS connector and then IG "ON".
  2. Measure voltage between signal terminal of OTS harness connector and chassis ground. (Measurement "A")
  3. Measure voltage between signal and ground terminals of OTS harness connector. (Measurement "B")

    Specification:  Voltage difference between measurement "A" and "B" is below 200mV.

    Fig 1: Measuring Voltage Between Signal Terminal Of OTS Harness Connector And Chassis Ground (Measurement A)
    G07251515Courtesy of HYUNDAI MOTOR CO.
    Fig 2: Measuring Voltage Between Signal And Ground Terminals Of OTS Harness Connector (Measurement B)
    G07251516Courtesy of HYUNDAI MOTOR CO.
  4. Is the measured voltage within specification?

    YES 

    NO