LEMON Manuals: Even more car manuals for everyone

Component Inspection

  1. Warm up the engine to normal operating temperature and check that HO2S signal is active.
  2. Connect Scan Tool and monitor the "RR OXYGEN SNSR-B1" parameter on the Scan Tool data list.

    Test Condition: Ignition "ON" & Engine "ON" & In Idle ("Closed Loop") condition

    Specification: Above 0.6V

    Fig 1: Monitoring "RR OXYGEN SNSR-B1" Parameter On Scan Tool Data List
    G03849484Courtesy of HYUNDAI MOTOR CO.
  3. Is sensor display within the specification?

    YES: 

    • Check for poor connection between ECM and component: backed out terminal, improper mating, broken locks or poor terminal to wire connection. Repair as necessary and go to "VERIFICATION OF VEHICLE REPAIR " procedure.

    NO: 

    • Check HO2S for contamination, deterioration, or damage. Substitute with a known-good HO2S and check for proper operation. If the problem is corrected, replace HO2S and then go to "VERIFICATION OF VEHICLE REPAIR " procedure.