LEMON Manuals: Even more car manuals for everyone

Back Up Lamp Switch Inspection

  1. Disconnect the back up lamp switch connector (A).
    Fig 1: Identifying Back Up Lamp Switch Connector
    G04891636Courtesy of HYUNDAI MOTOR CO.
  2. Inspect the continuity of the switch. When the shift lever is located in reverse range, it should be applied an electric current.
  3. Replace the back up lamp switch, if necessary.

    TORQUE:

    29.4~34.4 Nm (3.0~3.5 kgf.m, 21.7~25.3 lb-ft)