Ground Circuit Inspection
- IG "OFF" and disconnect ECTS connector.
- Measure voltage between terminal 3 of ECTS harness connector and chassis ground.
- Measure voltage between terminal 1 and 3 of ECTS harness connector.
Specification: Voltage difference between measurement "A" and "B" is below 200mV.
- Is the measured voltage within specification ?
YES
- Go to "SYSTEM INSPECTION " procedure.
NO
- Repair contact resistance and open in harness and go to "VERIFICATION OF VEHICLE REPAIR " procedure.