Monitor Scantool Data
- Ignition "ON" & Engine "OFF".
- Connect scan tool to Data Link Connector (DLC) and select "CLOSED TP SWITCH" parameter on scantool.
Specification: Throttle valve fully closed: ON
Throttle valve open a little: OFF
- Is "CLOSED TP SWITCH" value as specified?
YES
- Fault is intermittent caused by poor contact in Sensor's and/or PCM's connector or was repaired and PCM memory was not cleared. Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage. Repair or replace as necessary and go to "VERIFICATION OF VEHICLE REPAIR " procedure.
NO
- Go to "W/HARNESS INSPECTION " procedure.