HDS Function
DTC (PGM-FI)
Clear DTC (PGM-FI)
PGM-FI > Data List
Data List
Inspection
Secondary HO2S (Sensor 2) Component Inspection
Test Procedure
- Preparation
- Secondary HO2S (Sensor 2) connector (4P) : disconnected
- Procedure
- Perform the inspection according to the following table.
(Disconnected) Secondary HO2S (Sensor 2) connector (4P) female terminals IG Mode Normal Conditions Sensor internal circuit inspection OFF About 4.2 - 6.6 Ohm (at room temperature) OFF*1 Not shorted OFF*1 Not shorted *1: Secondary HO2S (Sensor 2) is installed
Results
- If it is abnormal, there is a problem with secondary HO2S (Sensor 2).
IG1 (SO2), SO2HT Circuit Inspection
Before disconnecting the PCM connector, jump the SCS line with the HDS, and wait more than 1 minute.
Test Procedure
- Preparation
- Secondary HO2S (Sensor 2) connector (4P) : disconnected
- PCM connector A (50P) : disconnected
- Procedure
- Perform the inspection according to the following table.
(Disconnected) Secondary HO2S (Sensor 2) connector (4P) male terminals (Disconnected) PCM connector A (50P) female terminals IG Mode Normal Conditions IG1 (SO2) circuit inspection ON 12 V battery voltage [ circuit type 1 ] SO2HT open wire inspection OFF There is less than 1 Ohm
Refer to the Open/Shorted Wire Inspection Description for the method to inspect the shorted circuit below, then start to inspect according to circumstances.SO2HT shorted to ground inspection OFF There is more than 1 MOhm
Results
- If abnormal, there is a problem in the circuit.
If the power supply inspection of the above table showed abnormally, do the additional Power Supply Inspection , to locate the failure.
PCM Inspection
Test Procedure
- If the other inspection item (s) indicated a normal condition, then it is determined that the remaining PCM is the cause.
Results
- There is a problem with the PCM.