HDS Function
DTC (PGM-FI)
Clear DTC (PGM-FI)
PGM-FI > Data List
Data List
| Signal | Current conditions (Values) | Current conditions (Unit) |
|---|---|---|
| HO2S S2 |
Inspection
SO2, SO2_SG [ SO2SG ] Circuit Inspection
Before disconnecting the PCM connector, jump the SCS line with the HDS, and wait more than 1 minute.
Test Procedure
- Preparation
- Secondary HO2S (Sensor 2) connector (4P) : disconnected
- PCM connector A (50P) : disconnected
- Procedure
- Perform the inspection according to the following table
(Disconnected) Secondary HO2S (Sensor 2) connector (4P) male terminals (Disconnected) PCM connector A (50P) female terminals IG Mode Normal Conditions SO2 open wire inspection OFF There is less than 1 Ohm SO2_SG [ SO2SG ] open wire inspection OFF There is less than 1 Ohm
Refer to the Open/Shorted Wire Inspection Description for the method to inspect the shorted circuit below, then start to inspect according to circumstances.SO2_SG [ SO2SG ] shorted to power inspection ON There is less than about 5 V
Results
- If abnormal, there is a problem in the circuit.
PCM Inspection
Preconditions
NOTE:
This procedure can be done before any other inspections are completed because this test procedure includes all of the following inspection items. However, if this test fails, it will be necessary to continue with each inspection item individually to determine which item failed.
- External circuit is normal
Test Procedure
Unit output voltage inspection
- Preparation
- Secondary HO2S (Sensor 2) connector (4P) : disconnected
- Procedure
- Jump the secondary HO2S (Sensor 2) connector (4P) terminals No. 1 and No. 2 with a jumper wire.
- Turn the vehicle to the ON mode.
- Confirm the HDS [ HO2S S2 ].
(Disconnected) Secondary HO2S (Sensor 2) connector (4P) male terminals
- Normal Conditions
- HDS [ HO2S S2 ] value is less than 3.28 V .
Results
- If it is abnormal, there is a problem with the PCM.
Secondary HO2S (Sensor 2) Inspection
Test Procedure
- If the other inspection item (s) indicated a normal condition, then it is determined that the remaining secondary HO2S (Sensor 2) is the cause.
Results
- There is a problem with secondary HO2S (Sensor 2).