HDS Function
DTC (PGM-FI)
Clear DTC (PGM-FI)
PGM-FI > Data List
Data List
Inspection
A/F Sensor (Sensor 1) Component Inspection
Test Procedure
- Preparation
- A/F sensor (Sensor 1) connector (6P) : disconnected
- Procedure
- Perform the inspection according to the following table.
(Disconnected) A/F sensor (Sensor 1) connector (6P) male terminals IG Mode Normal Conditions Sensor internal circuit inspection OFF About 2.8 - 4.5 Ohm (at room temperature) OFF*1 Not shorted OFF*1 Not shorted OFF*1 Not shorted OFF*1 Not shorted OFF*1 Not shorted OFF There is no continuity OFF There is no continuity OFF There is no continuity *1: A/F sensor (Sensor 1) is installed
Results
- If it is abnormal, there is a problem with the A/F sensor (Sensor 1).
IGPS (LAF) Circuit Inspection
Test Procedure
- Preparation
- A/F sensor (Sensor 1) connector (6P) : disconnected
- Procedure
- Perform the inspection according to the following table.
(Disconnected) A/F sensor (Sensor 1) connector (6P) female terminals IG Mode Normal Conditions IGPS (LAF) circuit inspection ON 12 V battery voltage [ circuit type 3 ]
Results
- If abnormal, there is a problem in the circuit.
If the power supply inspection of the above table showed abnormally, do the additional Power Supply Inspection , to locate the failure.
AFHT_N Circuit Inspection
Before disconnecting the PCM connector, jump the SCS line with the HDS, and wait more than 1 minute.
Test Procedure
- Preparation
- A/F sensor (Sensor 1) connector (6P) : disconnected
- PCM connector E (80P) : disconnected
- Procedure
- Perform the inspection according to the following table.
(Disconnected) A/F sensor (Sensor 1) connector (6P) female terminals (Disconnected) PCM connector E (80P) female terminals IG Mode Normal Conditions AFHT_N open wire inspection OFF There is less than 1 Ohm
Refer to the Open/Shorted Wire Inspection Description for the method to inspect the shorted circuit below, then start to inspect according to circumstances.AFHT_N shorted to ground inspection OFF There is more than 1 MOhm
Results
- If abnormal, there is a problem in the circuit.
PCM Inspection
Test Procedure
- If the other inspection item (s) indicated a normal condition, then it is determined that the PCM is the cause.
Results
- There is a problem with the PCM.