HDS Function
DTC (PGM-FI)
Clear DTC (PGM-FI)
PGM-FI > Data List
Data List
Inspection
VS Open Wire Inspection
Before disconnecting the PCM connector, jump the SCS line with the HDS, and wait more than 1 minute.
Test Procedure
- Preparation
- A/F sensor (Sensor 1) connector (6P) : disconnected
- PCM connector E (80P) : disconnected
- Procedure
- Perform the inspection according to the following table.
(Disconnected) A/F sensor (Sensor 1) connector (6P) female terminals (Disconnected) PCM connector E (80P) female terminals IG Mode Normal Conditions VS open wire inspection OFF There is less than 1 Ohm
Results
- If abnormal, there is a problem in the circuit.
PCM Inspection
Preconditions
NOTE:
This procedure can be done before any other inspections are completed because this test procedure includes all of the following inspection items. However, if this test fails, it will be necessary to continue with each inspection item individually to determine which item failed.
- External circuit is normal
Test Procedure
- Preparation
- A/F sensor (Sensor 1) connector (6P) : disconnected
- Procedure
- Perform the inspection according to the following table.
(Disconnected) A/F sensor (Sensor 1) connector (6P) female terminals IG Mode Normal Conditions Unit output voltage inspection ON*1 About 0.2 V or more *1: Engine running
Results
- If it is abnormal, there is a problem with the PCM.
A/F Sensor (Sensor 1) Inspection
Test Procedure
- If the other inspection item (s) indicated a normal condition, then it is determined that the A/F sensor (Sensor 1) is the cause.
Results
- There is a problem with the A/F sensor (Sensor 1).